home *** CD-ROM | disk | FTP | other *** search
/ NetNews Offline 2 / NetNews Offline Volume 2.iso / news / comp / sys / amiga / hardware-part1 / 9146 < prev    next >
Encoding:
Text File  |  1996-08-05  |  1.9 KB  |  36 lines

  1. Newsgroups: comp.periphs.scsi,comp.sys.sun.hardware,comp.sys.sgi.hardware,comp.sys.next.hardware,comp.sys.mac.hardware,comp.sys.ibm.ps2.hardware,comp.sys.ibm.pc.hardware.storage,comp.sys.ibm.pc.hardware.misc,comp.sys.ibm.pc.hardware,comp.sys.hp.hardware,comp.sys.amiga.hardware,comp.os.linux.hardware,biz.comp.hardware
  2. Path: musculus.mednet.gu.se!co
  3. From: co@musculus.mednet.gu.se (Christer Olsson)
  4. Subject: Re: HELP: Testing a Quantum SCSI harddisk.
  5. Message-ID: <1996Apr3.113208.20734@etek.chalmers.se>
  6. Sender: news@etek.chalmers.se (USENET News System)
  7. Organization: Chalmers University of Technology, Gothenburg, Sweden
  8. References:  <50077815@wbmt41.wbmt.tudelft.nl>
  9. Date: Wed, 3 Apr 96 11:32:08 GMT
  10.  
  11. In article <50077815@wbmt41.wbmt.tudelft.nl>, "Marcel Offermans" <marcel@wbmt41.wbmt.tudelft.nl> writes:
  12.  
  13. |> My question: Is the Norton diskdoctor test thorough? I mean, can a drive be
  14. |> defective (looking at the SCSI specs) without this defect showing up in the
  15. |> test?
  16. |> 
  17.  
  18. Yes, a possible problem is the inbuilt terminator if the drive uses such and
  19. they┤re jumpered. If the terminator is faulty and cannot be disabled, you
  20. may get alot of problems when connecting the drive to a chain with a proper
  21. terminator. And the vendor cannot find any problems when they tries the 
  22. drive with the inbuilt terminator.
  23.  
  24. Another problem may be the SCSI-addressing. If the circuit is faulty, 
  25. the bus will lock if the drive is connected into a chain with other
  26. drives, but may works fine alone.
  27.  
  28. If I could, I should test the drive alone and with inbuilt terminator
  29. to see if it┤s possible to catch the fault. 
  30.  
  31. Home:                I Work:                I        cellular: 0707-405393
  32. Christer Olsson      I MedNet               I        day:   +46+31-7733760
  33. Kaggeledsgatan 11    I Medicinaregatan 7b   I        night: +46+31-843740
  34. S-416 74  Gothenburg I S-413 90  Gothenburg I        fax:   +46+31-7733758
  35.           Sweden     I           Sweden     I Email: co@mednet.gu.se
  36.